E-mail Print PDF

Central Vacuum Cleaner Systems

Multistage Vacuum Turbines for Multiple Operations

central_vac

  • Explosion-Proof or Standard versions available
  • Available with Manual Filter Shaker system (MFS) or automatic filtation cleaning options (AFS) (APS)
  • Stainless Steel construction available
Tiger-Vac offers practical and cost-effective products as well as complete central vacuum cleaner system solutions for a wide range of applications and industries. We can assist you in the design of a central vacuum cleaner system suited to your requirements and meeting the most stringent safety regulations and quality standards.

Explosion proof/Dust ignition proof Central Filtration Recovery units:

FRS-10/40L EX *Pharma - Dry Recovery
  • For 2.2 kW to 5 kW motor performance
  • Stainless steel AISI 304 construction
  • AISI 316 Electropolished available
  • Compable with CD-5 EX Series
  • Manual (MRP) or Automatic (ARP) reverse purge filter cleaning system with 1 cartridge & skirt
    • cartridge filter surface: 37 200 cm² (40 ft²)
    • skirt filter surface:         3 330 cm² (3.58 ft²)
    • total filter surface:         40 530 cm² (43.58 ft²)
  • Also available with Manual Filter Shaker (MFS) System
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Available non-explosion proof
  • Recovery Capacity 10 gallons (40 litres)
  • Contact us for more information

All stainless steel construction.  This Filtration Recovery System is cleanroom compatible when equipped with a HEPA (H14)/ULPA (U15) Filter and can be used in the pharmaceutical industry.  For metal dust recovery, it is recommended that this unit be used in conjunction with an immersion separator.  Must be used in conjunction with a power source.  This unit is available with a Manual Filter Shaker, Manual Reverse Purge System or Automatic Reverse Purge System.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.995% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 microns or larger.

Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.

ARP - Automatic Reverse Purge

ARP

The Automatic Reverse Purge System requires a small 2 HP compressor on a 1/4" air line hose @ 5 bar (80 psi), 3.78 l/s (8 cfm) to feed the system. This system is ideal when the vacuum cleaner will be attached to a processing system and the operator does not have the time to continually perform a manual purge. A flap has been installed inside of the suction port and will close automatically when the vacuum cleaner is turned off, thus eliminating the risk that any powders or debris will escape from the unit when operating the ARP without any suction power.

MFS - Manual Filter Shaker System

MFS_top
(illustration shows a top-mounted shaker)

The Manual Fitler Shaker system allows the operator to clean the main filter without having to open the vacuum cleaner.  This shaker System reduces maintenance down time.

The Manual Filter Shaker System consists of a spring action mechanism operating directly onto the filter cage located inside of the filter chamber. The system is operated by pressing on the ergonomic handle located on the side or top of the filter chamber.

The Manual Filter Shaker dislodges the accumulated caked-on dust from the filter thus improving the filter’s performance.

The filter, along with the filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

MRP - Manual Reverse Purge System

MRPThe Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge.  By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts.  This Purging System reduces maintenance down time.

The Manual Reverse Purge (MRP) works by :

1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.

2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.

Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).

Reverse Purge System will cause dust to fall off of the filter.

Name Description Link
No documents currently available for this model
FRS-15/63L EX *Pharma - Dry Recovery
  • For 2.2 kW to 5 kW motor performance
  • Stainless steel AISI 304 construction
  • AISI 316 Electropolished available
  • Compable with CD-5 EX Series
  • Manual (MRP) or Automatic (ARP) reverse purge filter cleaning system with 1 cartridge & skirt
    • cartridge filter surface: 37 200 cm² (40 ft²)
    • skirt filter surface:         3 330 cm² (3.58 ft²)
    • total filter surface:         40 530 cm² (43.58 ft²)
  • Also available with Manual Filter Shaker (MFS) System
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Available non-explosion proof
  • Recovery Capacity 15 gallons (63 litres)
  • Contact us for more information

All stainless steel construction.  This Filtration Recovery System is cleanroom compatible when equipped with a HEPA (H14)/ULPA (U15) Filter and can be used in the pharmaceutical industry.  For metal dust recovery, it is recommended that this unit be used in conjunction with an immersion separator.  Must be used in conjunction with a power source.  This unit is available with a Manual Filter Shaker, Manual Reverse Purge System or Automatic Reverse Purge System.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.995% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 microns or larger.

Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.

ARP - Automatic Reverse Purge

ARP

The Automatic Reverse Purge System requires a small 2 HP compressor on a 1/4" air line hose @ 5 bar (80 psi), 3.78 l/s (8 cfm) to feed the system. This system is ideal when the vacuum cleaner will be attached to a processing system and the operator does not have the time to continually perform a manual purge. A flap has been installed inside of the suction port and will close automatically when the vacuum cleaner is turned off, thus eliminating the risk that any powders or debris will escape from the unit when operating the ARP without any suction power.

MFS - Manual Filter Shaker System

MFS_top
(illustration shows a top-mounted shaker)

The Manual Fitler Shaker system allows the operator to clean the main filter without having to open the vacuum cleaner.  This shaker System reduces maintenance down time.

The Manual Filter Shaker System consists of a spring action mechanism operating directly onto the filter cage located inside of the filter chamber. The system is operated by pressing on the ergonomic handle located on the side or top of the filter chamber.

The Manual Filter Shaker dislodges the accumulated caked-on dust from the filter thus improving the filter’s performance.

The filter, along with the filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

MRP - Manual Reverse Purge System

MRPThe Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge.  By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts.  This Purging System reduces maintenance down time.

The Manual Reverse Purge (MRP) works by :

1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.

2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.

Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).

Reverse Purge System will cause dust to fall off of the filter.

Name Description Link
No documents currently available for this model
FRS-63L EX EXTENDED *Pharma - Dry Recovery
  • For 7.5 kW motor performance
  • Stainless steel AISI 304 construction
  • AISI 316 Electropolished available
  • Compable with CD-7 EX Series
  • Extended Series
  • Manual (MRP) or Automatic (ARP) reverse purge filter cleaning system with 1 cartridge & skirt
    • cartridge filter surface: 55 700 cm² (60 ft²)
    • skirt filter surface: 5 110 cm² (5.5 ft²)
    • total filter surface: 60 810 cm² (65.5 ft²)
  • Also available with Manual Filter Shaker (MFS) System
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Available non-explosion proof
  • Recovery Capacity 15 gallons (63 litres)
  • Contact us for more information

All stainless steel construction.  This Filtration Recovery System is cleanroom compatigle when equipped with a HEPA (H14)/ULPA (U15) Filter and can be used in the pharmaceutical industry.  For metal dust recovery, it is recommended that this unit be used in conjunction with an immersion separator.  Must be used in conjunction with a power source.  This unit is available with a Manual Filter Shaker, Manual Reverse Purge System or Automatic Reverse Purge System.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.995% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 microns or larger.

Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.

ARP - Automatic Reverse Purge

ARP

The Automatic Reverse Purge System requires a small 2 HP compressor on a 1/4" air line hose @ 5 bar (80 psi), 3.78 l/s (8 cfm) to feed the system. This system is ideal when the vacuum cleaner will be attached to a processing system and the operator does not have the time to continually perform a manual purge. A flap has been installed inside of the suction port and will close automatically when the vacuum cleaner is turned off, thus eliminating the risk that any powders or debris will escape from the unit when operating the ARP without any suction power.

MFS - Manual Filter Shaker System

MFS_top
(illustration shows a top-mounted shaker)

The Manual Fitler Shaker system allows the operator to clean the main filter without having to open the vacuum cleaner.  This shaker System reduces maintenance down time.

The Manual Filter Shaker System consists of a spring action mechanism operating directly onto the filter cage located inside of the filter chamber. The system is operated by pressing on the ergonomic handle located on the side or top of the filter chamber.

The Manual Filter Shaker dislodges the accumulated caked-on dust from the filter thus improving the filter’s performance.

The filter, along with the filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

MRP - Manual Reverse Purge System

MRPThe Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge.  By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts.  This Purging System reduces maintenance down time.

The Manual Reverse Purge (MRP) works by :

1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.

2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.

Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).

Reverse Purge System will cause dust to fall off of the filter.

Name Description Link
No documents currently available for this model
FRS-40/160L EX *Pharma - Dry Recovery
  • For 7.5 kW to 15 kW motor performance
  • Stainless steel AISI 304 construction
  • AISI 316 Electropolished available
  • Compable with CD-10 EX Series
  • Automatic Purge (APS) filter cleaning system with 4 cartridges & 4 skirts
    • Total cartridge filter surface: 111 483 cm² (120 ft²)
    • Total skirt filter surface:         20 840 cm² (22.44 ft²)
    • total filter surface:         132 323 cm² (142.44 ft²)
  • Also available with Automatic Filter Shaker (AFS) System or Automatic Reverse Pulse (RPS) System
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Available non-explosion proof
  • Recovery Capacity 40 gallons (160 litres)
  • Contact us for more information

All stainless steel construction.  This Filtration Recovery System is cleanroom compatible when equipped with a HEPA (H14)/ULPA (U15) Filter and can be used in the pharmaceutical industry.  For metal dust recovery, it is recommended that this unit be used in conjunction with an immersion separator.  Must be used in conjunction with a power source.  This unit is available with an Automatic Filter Shaker, Automatic Reverse Pulse System or Automatic Purge System.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.995% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 microns or larger.

Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.

APS - Automatic Purge system

Explosion proof Automatic Purge system (Pneumatic Timers)

APS_control_panel
A full immersion system for hazardous areas, consisting of a round header tank with fully integrated diaphragm valves, is built inside of the filter chamber. The system operates with filtered, oil-free compressed air. The diaphragm valves are opened in sequence by a solenoid valve controlled by pneumatic (air) operated timers located outside of the filter chamber.

A short pulse of compressed air is injected into the top of theStatic dissipating and conductive PTFE laminated filter catridges creating a stronger airflow downward moving pressure wave. This wave breaks up the accumulated dust that is caked onto the cartridges.

The pneumatically (air) operated controls, located outside of the filter chamber, allow only one cartridge to be cleaned at any give time, thus ensuring that the vacuum cleaner operates continuously.

Industrial Automatic Purge System (Electric Timers)

auto_pulse

A short pulse of compressed air is injected into the top of the filter cartridges creating a stronger wave of airflow pressure which moves downward into the filters and breaks up the accumulated dust that is caked onto the cartridges.

The electrically operated controls, located outside of the filter chamber, allow only one cartridge to be cleaned at any give time, thus ensuring that the vacuum cleaner operates continuously.

AFS - Automatic Filter Shaker

AFS_control_panelA Filter Shaker system for hazardous areas consisting of a double acting air cylinder operating directly onto the stainless steel filter cage located inside of the filter chamber. The system is operated by filtered, oil-free compressed air. The frequency of the shaking cycle is controlled by pneumatic (air) operated timers located outside of the filter chamber.

Short strokes are applied to the filter cage freeing the accumulated caked on dust from the Static dissipating and conductive polyester flourocarbon treated filter and allowing them to flow out, thus ensuring continuous duty and minimizing friction loss filter performance.

The Static dissipating and conductive polyester flourocarbon treated filter, along with the stainless steel filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

RPS - Reverse Pulse System

RPS

  • Automatic filter cleaning system that helps remove caked-on dust from the filter.
  • Pulsed air is blown from the inside towards the outside of the filter at a regular frequence.
  • User can adjust the interval between the two cleaning cycles.
  • Pneumatically (air) operated.
Name Description Link
No documents currently available for this model
CDPU-5/7/10 EX *Pharma - Continuous Duty Power Unit

ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X – T135oC
LCIE 03 ATEX 6295

  • Legally certified explosion proof/dust ignition proof vacuum cleaner.  Less than 10 Ohms of resistivity
  • ULPA Filtration U15/HEPA Filtration H14 available
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Continuous duty 3-phase explosion proof motor
  • Power Unit can be attached to a Filtration System (FRS)
  • Can be used as a mobile or central unit
  • All stainless steel construction
  • Equipped with 4 wheels for easy manoeuverability.  Can also be equipped with slots for fork lift capability
  • Brochure
  • Certificate

All stainless steel construction.  Less than 10 Ohms of resistivity.  This unit can be equipped with a true ULPA Filter (U15) or HEPA Filter (H14) located either downstream or upstream outside of the motor housing.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  This unit can be used in hazardous locations and can be used as either a mobile or central unit.  It can also be hooked up to a Filtration System (FRS).  All of our ULPA/HEPA Power Units are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.995% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 microns or larger.

Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

Name Description Link
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download

 

Note:

HEPA Filters - efficiency of 99.995% on 0.3 microns - Tested IEST RP-CC001.3 - H14 as per MPPS method EN 1822.

ULPA Filters - efficiency of 99.999% on 0.3 microns - Filtration efficiency of 99.9995% on 0.18 microns - Tested IEST RP-CC001.3 - U15 as per MPPS method EN 1822

Please be advised that all Tiger-Vac HEPA/ULPA Filters are DOP tested when assembled, either upstream or downstream, inside of the vacuum cleaners.

All Tiger-Vac HEPA/ULPA Filters are assembled mechanically with 3 bolts and include a specially designed memory gasket in order to prevent any leaks during the life span of the gasket thus insuring the health and safety of the end user.











');
 
With forty years of experience, Tiger-Vac has successfully established itself in the international market as a manufacturer of high-quality industrial, explosion proof, cleanroom and ATEX, IECEx, NFPA-NEC compliant vacuum cleaner systems for contamination controlled environments & hazardous areas.