E-mail Print PDF

Cleanroom Vacuum Cleaner Systems - Pharma
ULPA Filter efficiency of 99.999% on 0.12 micron

  • All vacuum cleaner systems featured on this page meet requirements for use in ISO Class 4 (former Class 10) Cleanroom.

Electric Series

MV-1CR (HH-CC) *Pharma - Dry Recovery
  • ULPA Filtration U15
  • *Cleanroom compatible with ISO Class 4 (former Class 10).  Can be used in the pharmaceutical industry
  • Static free and ESD safe.  EMI/RFI Shielded.  Electrical resistivity is less than 10 Ohms
  • 4-stage filtration system includes an ULPA Filter U15, Cloth Filter, Dome Filter and Disposable Filter Bag
  • Special filter lined with stainless steel is available for the recovery of broken wafers and sharp objects
  • Designed for general cleanup in contamination controlled environments
  • Single phase thru-flow motor
  • For dry recovery only
  • All stainless steel construction
  • Recovery capacity of 0.5 gallons (2 liters) in Disposable Filter Bag
  • Equipped with a shoulder strap and carrying case
  • Complete tool kit included
  • Brochure (North-America)
  • Brochure (Europe)

All stainless steel construction.  This unit is equipped with a true ULPA Filter (U15) located upstream of the motor.  This unit is EMI/RFI Shielded and will not disrupt computers and other sensitive electronic equipment.  This unit is static free and ESD safe and has an electrical resistivity of less than 10 Ohmas.  Any static produced while vacuuming is quickly and effectively discharged to the ground.  This unit is cleanromm compatible and can be used in the pharmaceutical industry.  This unit is designed for general cleanup in contamination controlled environments.  This is a dry only vacuum cleaner.  All of our ULPA vacuum cleaners are DOP Leak Tested before leaving our facility.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

EMI - EMI Suppresion / RFI Shielding

These cleanroom vacuum cleaners are equipped with an electronic filter suppresser which reduces electromagnetic interference (EMI), both radiated and conducted, below class B limits for digital apparatus as established by the FCC and ISO.  It also provides shielding against RFI (Radio Frequency Interference).  The electronic filter is wired in line with the motor.  If the electronic filter should fail, power to the motor will automatically be cut-off.  These vacuum cleaners will not disrupt computers, radio and video monitors and other sensitive electronic equipment.

Name Description Link
No documents currently available for this model
MV-1 CR (HH) *Pharma - Dry Recovery
  • ULPA Filtration U15
  • *Cleanroom compatible with ISO Class 4 (former Class 10).  Can be used in the pharmaceutical industry
  • Static free and ESD safe.  EMI/RFI Shielded.  Electrical resistivity is less than 10 Ohms
  • 4-stage filtration system includes an ULPA Filter U15, Cloth Filter, Dome Filter and Disposable Filter Bag
  • Special filter lined with stainless steel is available for the recovery of broken wafers and sharp objects
  • Designed for general cleanup in contamination controlled environments
  • Single phase thru-flow motor
  • For dry recovery only
  • All stainless steel construction
  • Recovery capacity of 0.5 gallon (2 liters) in Disposable Filter Bag
  • Equipped with a shoulder strap
  • Complete tool kit included
  • Brochure (North-America)
  • Brochure (Europe)

All stainless steel construction.  This unit is equipped with a true ULPA Filter (U15) located upstream of the motor.  This unit is EMI/RFI Shielded and will not disrupt computers and other sensitive electronic equipment.  This unit is static free and ESD safe and has an electrical resistivity of less than 10 Ohmas.  Any static produced while vacuuming is quickly and effectively discharged to the ground.  This unit is cleanromm compatible and can be used in the pharmaceutical industry.  This unit is designed for general cleanup in contamination controlled environments.  This is a dry only vacuum cleaner.  All of our ULPA vacuum cleaners are DOP Leak Tested before leaving our facility.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

EMI - EMI Suppresion / RFI Shielding

These cleanroom vacuum cleaners are equipped with an electronic filter suppresser which reduces electromagnetic interference (EMI), both radiated and conducted, below class B limits for digital apparatus as established by the FCC and ISO.  It also provides shielding against RFI (Radio Frequency Interference).  The electronic filter is wired in line with the motor.  If the electronic filter should fail, power to the motor will automatically be cut-off.  These vacuum cleaners will not disrupt computers, radio and video monitors and other sensitive electronic equipment.

Name Description Link
No documents currently available for this model
MV-1 CR (GC) *Pharma - Dry Recovery
  • ULPA Filtration U15
  • *Cleanroom compatible with ISO Class 4 (former Class 10).  Can be used in the pharmaceutical industry
  • Static free and ESD safe.  EMI/RFI Shielded.  Electrical resistivity is less than 10 Ohms
  • 4-stage filtration system includes an ULPA Filter U15, Cloth Filter, Dome Filter and Disposable Filter Bag
  • Special filter lined with stainless steel is available for the recovery of broken wafers and sharp objects
  • Designed for general cleanup in contamination controlled environments
  • Single phase thru-flow motor
  • For dry recovery only
  • All stainless steel construction
  • Recovery capacity of 1.5 gallon (5.7 liters) in Disposable Filter Bag
  • Equipped with a golf cart for easy maneuverability
  • Complete tool kit included
  • Brochure (North-America)
  • Brochure (Europe)

All stainless steel construction.  This unit is equipped with a true ULPA Filter (U15) located upstream of the motor.  This unit is EMI/RFI Shielded and will not disrupt computers and other sensitive electronic equipment.  This unit is static free and ESD safe and has an electrical resistivity of less than 10 Ohmas.  Any static produced while vacuuming is quickly and effectively discharged to the ground.  This unit is cleanromm compatible and can be used in the pharmaceutical industry.  This unit is designed for general cleanup in contamination controlled environments.  This is a dry only vacuum cleaner.  All of our ULPA vacuum cleaners are DOP Leak Tested before leaving our facility.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

EMI - EMI Suppresion / RFI Shielding

These cleanroom vacuum cleaners are equipped with an electronic filter suppresser which reduces electromagnetic interference (EMI), both radiated and conducted, below class B limits for digital apparatus as established by the FCC and ISO.  It also provides shielding against RFI (Radio Frequency Interference).  The electronic filter is wired in line with the motor.  If the electronic filter should fail, power to the motor will automatically be cut-off.  These vacuum cleaners will not disrupt computers, radio and video monitors and other sensitive electronic equipment.

Name Description Link
No documents currently available for this model
MV-1 CR (BP) *Pharma - Dry Recovery
  • ULPA Filtration U15
  • *Cleanroom compatible with ISO Class 4 (former Class 10).  Can be used in the pharmaceutical industry
  • Static free and ESD safe.  EMI/RFI Shielded.  Electrical resistivity is less than 10 Ohms
  • 4-stage filtration system includes an ULPA Filter U15, Cloth Filter, Dome Filter and Disposable Filter Bag
  • Special filter lined with stainless steel is available for the recovery of broken wafers and sharp objects
  • Designed for general cleanup in contamination controlled environments
  • Single phase thru-flow motor
  • For dry recovery only
  • All stainless steel construction
  • Recovery capacity of 1.5 gallon (5.7 liters) in Disposable Filter Bag
  • Equipped with a backpack harness
  • Complete tool kit included
  • Brochure (North-America)
  • Brochure (Europe)

All stainless steel construction.  This unit is equipped with a true ULPA Filter (U15) located upstream of the motor.  This unit is EMI/RFI Shielded and will not disrupt computers and other sensitive electronic equipment.  This unit is static free and ESD safe and has an electrical resistivity of less than 10 Ohmas.  Any static produced while vacuuming is quickly and effectively discharged to the ground.  This unit is cleanromm compatible and can be used in the pharmaceutical industry.  This unit is designed for general cleanup in contamination controlled environments.  This is a dry only vacuum cleaner.  All of our ULPA vacuum cleaners are DOP Leak Tested before leaving our facility.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

EMI - EMI Suppresion / RFI Shielding

These cleanroom vacuum cleaners are equipped with an electronic filter suppresser which reduces electromagnetic interference (EMI), both radiated and conducted, below class B limits for digital apparatus as established by the FCC and ISO.  It also provides shielding against RFI (Radio Frequency Interference).  The electronic filter is wired in line with the motor.  If the electronic filter should fail, power to the motor will automatically be cut-off.  These vacuum cleaners will not disrupt computers, radio and video monitors and other sensitive electronic equipment.

Name Description Link
No documents currently available for this model




cr-1000CR-1000 ULPA
Dry Recovery

 

 

  • ULPA filtration
  • Safe-containment canister
  • 3 Tools and accessories kit to choose from
  • High performance, low cost
  • For dry recovery only
  • Brochure

CR-1_tnCR-1
Dry Recovery

 

 

  • ULPA filtration
  • Lightweight, non metal construction
  • Tool kit and accessories included
  • Also available with stainless steel recovery tank
  • High performance, low cost
  • For dry recovery only
  • Brochure
  • Declaration of conformity
  • Slideshow

EMI-CWR_tnEMI-CWR
Dry recovery

 

 

  • ULPA Filtration
  • Static Free RFI Shielded and EMI suppression
  • Chrome plated steel construction (stainless steel-pharma available)
  • Tool kit and accessories included
  • For dry recovery only
  • Brochure
  • Slideshow

 

CR4D_tnCR-4D
Dry Recovery

 

 

  • ULPA Filtration
  • High density polyethylene recovery tank with chrome plated motor head
  • Tool kit and accessories included
  • For dry recovery only
  • Brochure
  • Slideshow

CWR-10_tnCWR PHARMA series
Wet and dry recovery

 

 

 

  • Dual ULPA filtration
  • EMI/RFI shielded, static free and ESD safe
  • CWR 10/15 (4W) MR is available with a middle ring (MRAC)
  • All stainless steel 304 electropolished autoclavable recovery tank and floater system
  • Polyethylene tank available
  • Available with optional needle/glass trap
  • Tool kit and accessories included
  • For wet and dry recovery
  • Brochure
  • Slideshow
  • Needle/Glass trap: brochure

 

pharmavac_tnPharmavac
Liquid recovery with broken ampules and glass

 

 

 

  • Dual ULPA filtration
  • Broken ampules and glass are separated from liquid in an autoclavable basket
  • All electropolished stainless steel 304/316. Vacuum components (except motor head) and accessories are completely autoclavable
  • For liquid recovery with broken ampules and glass
  • Brochure
  • Slideshow

 

CD-1500-STD_allstainlessCD 1500/1501 CR (STD) PHARMA
Dry recovery

 

 

 

  • ULPA filtration. Internal HEPA filter is available
  • Continuous duty single and 3-phase motor
  • Heavy duty powder coated construction. Also available in Stainless Steel AISI 304 construction (recovery tank or complete unit)
  • Also available for Category 2 potentially explosive atmospheres
  • For dry recovery only
  • CD-1500: Brochure / Slideshow
  • CD-1501: Brochure / Slideshow

 

CD-2600-EX-CR-ARPCD-2600 CR STD (MFS/MRP) PHARMA
Dry recovery

 

 

 

  • HEPA/ULPA filtration
  • Continuous duty single and 3-phase motor
  • Heavy duty powder coated construction. Also available in Stainless Steel AISI 304 construction (recovery tank or complete unit)
  • Available with Manual Filter Shaker (MFS), Manual Reverse Purge (MRP) or Automatic Reverse Purge (ARP)
  • Also available for Category 2 potentially explosive atmospheres
  • For dry recovery only
  • CD-2600 MFS: Brochure / Slideshow
  • CD-2600 MRP: Brochure / Slideshow
  • CD-2600 ARP: Brochure / Slideshow

 

CD-1-EX-CR-DFB-ULPACD-1 EX
Dry recovery

CE 0081 EX II 2 G/D EEx d IIB T4
IP6X – T135°C
LCIE 03 ATEX 6295

 

  • ATEX 100a, 94/9/EC, cat. 2 - ATEX Zone 1 (Gas) and Zone 21 (Dust)
  • ULPA or HEPA filtration available
  • Continuous duty 3-phase motor
  • Stainless steel AISI 304/316 construction. Autoclavable electropolished recovery tank
  • For dry recovery only
  • Contact us for more information
  • Declaration of conformity
  • Brochure

 

CD-2_EX_MRAC_ULPACD-2 PHARMA Series
Wet and Dry recovery

CE 0081 EX II 2 G/D EEx d IIB T4
IP6X – T135°C
LCIE 03 ATEX 6295
  • ATEX 100a, 94/9/EC, cat. 2 - ATEX Zone 1 (Gas) and Zone 21 (Dust)
  • ULPA filtration
  • Continuous duty 3-phase motor
  • Middle Ring with Activated Carbon (MRAC) for wet and dry recovery
  • Stainless steel AISI 304/316 construction. Autoclavable electropolished recovery tank and middle ring
  • For wet and dry recovery
  • Contact us for more information
  • Declaration of conformity
  • Brochure

 

EUR-50_MRPEUR PHARMA Series
Dry recovery

CE 0081 EX II 2 G/D EEx d IIB T4
IP6X – T135°C
LCIE 03 ATEX 6295

 

  • ATEX 100a, 94/9/EC, cat. 2 - ATEX Zone 1 (Gas) and Zone 21 (Dust). Also available for ATEX Zone 21 (dust) and ATEX Zone 22 (dust)
  • Suitable for pharmaceutical industries
  • Optional HEPA/ULPA filter
  • Continuous duty single or 3-phase motor
  • Equipped with Manual Reverse Purge (MRP), Automatic Reverse Purge (ARP) available
  • All stainless steel AISI 304 construction (AISI 316L electropolished available)
  • Detachable recovery tank (DT)
  • For dry recovery only
  • Brochure
  • Slideshow

 

EXP1-10-CR_TNEXP1-10/15 EX CR PHARMA
Wet and dry recovery

CE 0081 EX II 2 G/D EEx d IIA T3
IP6X – T200°C
LCIE 03 ATEX 6297

 

  • ATEX 100a, 94/9/EC, cat. 2 - ATEX Zone 1 (Gas), Zone 21 (Dust)
  • ULPA filtration
  • Available with Middle Ring with Activated Carbon (MRAC)
  • All stainless steel AISI 304/316 construction. Stainless steel tools and accessories
  • Autoclavable recovery tank. Autoclavable tools and accessories available
  • For wet and dry recovery
  • Brochure
  • Declaration of conformity
  • Slideshow

 

 

 


Pneumatic (Air) Series

SS-10-CRSS-10/15 EX CR PHARMA
Wet and dry recovery

CE EX II 2 G/D c IIC T6 (85°C)
LCIE 03 ATEX 6310

 

  • ATEX 100a, 94/9/EC, cat. 2 - ATEX Zone 1 (Gas) and Zone 21 (Dust)
  • ULPA filtration
  • Available with Middle Ring with Activated Carbon (MRAC)
  • All stainless steel AISI 304/316 construction. Stainless steel tools and accessories
  • Autoclavable recovery tank. Autoclavable tools and accessories
  • For wet and dry recovery
  • Brochure
  • Declaration of conformity
  • Slideshow

 

Cleanroom Recovery Units


LARU-15_SS_MRACLARU-10 (4W) with MRAC

 

 

 

  • Cleanroom compatible recovery units for liquids (LARU)
  • Made of stainless steel 304/316 (LARU)
  • LARU is completely autoclavable (except filters)
  • Available on a 4-wheel dolly
  • Available with a Middle Ring with Kina 3®
  • Designed to be used in conjunction with a vacuum cleaner
  • Slideshow (LARU)
  • Slideshow (LARU with middle-ring)
  • Contact us for more information
brand activated carbon for the adsorption of vapours

 

LARU-15_SS_MRACLARU-10 (4W)

 

 

 

  • Cleanroom compatible recovery units for liquids (LARU)
  • Made of stainless steel 304/316 (LARU)
  • LARU is completely autoclavable (except filters)
  • Available on a 4-wheel dolly
  • Designed to be used in conjunction with a vacuum cleaner
  • Slideshow (LARU)
  • Slideshow (LARU with middle-ring)
  • Contact us for more information

LARU-15_SS_MRACARU-10 (4W) with MRAC

 

 


  • Cleanroom compatible recovery units for corrossive liquids (ARU)
  • Made of Polyethylene and Nylon (ARU).
  • Available on a 4-wheel dolly
  • Available with a Middle Ring with Kina 3® brand activated carbon for the adsorption of vapours
  • Designed to be used in conjunction with a vacuum cleaner
  • Contact us for more information

aruARU-10 (4W)

 

 


  • Cleanroom compatible recovery units for acids & corrossive liquids (ARU)
  • Made of Polyethylene and Nylon (ARU).
  • Available on a 4-wheel dolly
  • Designed to be used in conjunction with a vacuum cleaner
  • Contact us for more information
INT-5CR_small

INT-5 (CR) For Liquid recovery

 

 

  • Interceptor Attachment for liquid recovery - cleanroom version
  • Designed to be used in conjunction with cleanroom vacuum cleaner systems.
  • Stainless steel lid and floater housing - floater cuts off suction when liquids reach capacity level.
  • Polyethylene recovery tank.
  • Contact us for more information.

 

Note:

HEPA Filters - efficiency of 99.995% on 0.3 microns - Tested IEST RP-CC001.3 - H14 as per MPPS method EN 1822.

ULPA Filters - efficiency of 99.999% on 0.3 microns - Filtration efficiency of 99.9995% on 0.18 microns - Tested IEST RP-CC001.3 - U15 as per MPPS method EN 1822

Please be advised that all Tiger-Vac HEPA/ULPA Filters are DOP tested when assembled, either upstream or downstream, inside of the vacuum cleaners.

All Tiger-Vac HEPA/ULPA Filters are assembled mechanically with 3 bolts and include a specially designed memory gasket in order to prevent any leaks during the life span of the gasket thus insuring the health and safety of the end user.

 
With forty years of experience, Tiger-Vac has successfully established itself in the international market as a manufacturer of high-quality industrial, explosion proof, cleanroom and ATEX, IECEx, NFPA-NEC compliant vacuum cleaner systems for contamination controlled environments & hazardous areas.