Tiger-Vac, como fabricante GARANTIZA que sus aspiradores de catégoria 1 y 2, pueden ser Útilizados para récuperar con toda seguridad polvos combustibles/conductivos y/o liquidos inflamables.
La marcacion ATEX certificada por medio de su indice de proteccion(IP),la capacidad del aspirador de estar en presencia donde hay polvos combustibles/conductivos y/o liquidos inflamables. pero no certifica la capacidad del aspirador para récuperar dichos materiales.
Shooting Range Explosion Proof Vacuum Cleaner Systems (ATEX 100a Dir. 94/9/EC compliant)
Aspiradores Categoria 2 Antidéflagrantes à prueba de inflammaciones de polvo explosivo ATEX Zona 1 (Gas) y ATEX Zona 21 (Polvo)
Electric Series

0081
II 2 G/D Ex d IIA T3 Ex tD A21
IP6X – T 200°C
LCIE 03 ATEX 6297

IP65 – T 120°C
LCIE 03 ATEX 6297
- Legally certified explosion proof/dust ignition proof vacuum cleaner
- Less than 10 Ohms of resistivity
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- Designed for the recovery of flammable and toxic powders such as unspent gunpowder and lead contaminants
- Ideal for shooting ranges, army ammunition depots, manufacturers of firearms and pyrotechnic industries
- Single phase explosion proof/dust ignition proof motor
- Available with Manual Filter Shaker (MFS) system
- For dry recovery only
- All stainless steel AISI 304 construction (except cart). Stainless steel cart available
- Detachable recovery tank (DT) for easy disposal of recovered materials. Recovery capacity of 6.25 gallons (25 liters)
- Poly Liner and retainer clip included for the easy and safe disposal of recovered materials
- Equipped with a 4-wheel cart
- Complete static dissipating tool kit and suction hose included
| Name | Description | Download |
| EXP1-20L (DT) RE HEPA (FR-P) Brochure (Metric) | Technical data for EXP1-20L (DT) RE HEPA (FR-P) in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| EXP1-20L (DT) RE HEPA (FR-P) Brochure (Imperial) | Technical data for EXP1-20L (DT) RE HEPA (FR-P) in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| ATEX Vacuum Cleaners electrically operated singlephase T3 | Certification Document | descargar |

0081
II 2 G/D Ex d IIA T3 Ex tD A21
IP6X – T 200°C
LCIE 03 ATEX 6297

IP65 – T 120°C
LCIE 03 ATEX 6297
- Legally certified explosion proof/dust ignition proof vacuum cleaner
- Less than 10 Ohms of resistivity
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- *Cleanroom compatible. Can be used in the pharmaceutical industry with optional stainless steel cart
- Designed for applications where finely pulverized dust is to be recovered
- Single phase explosion proof/dust ignition proof motor
- Available with Manual Reverse Purge (MRP) system
- For dry recovery only
- All stainless steel AISI 304 construction (except cart). Stainless steel cart available
- Detachable recovery tank (DT) for easy disposal of recovered materials. Recovery capacity of 8.75 gallons (35 liters)
- Poly liner and clip included for the easy and safe disposal of recovered materials
- Equipped with a 4-wheel cart and wire tool basket
- Complete static dissipating tool kit and suction hose included
MRP - Manual Reverse Purge System
The Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge. By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts. This Purging System reduces maintenance down time.
The Manual Reverse Purge (MRP) works by :
1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.
2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.
Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).
Reverse Purge System will cause dust to fall off of the filter.
| Name | Description | Download |
| EXP1-35L (DT) RE HEPA (MRP) Brochure (Metric) | Technical data for EXP1-35L (DT) RE HEPA (MRP) in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| EXP1-35L (DT) RE HEPA (MRP) Brochure (Imperial) | Technical data for EXP1-35L (DT) RE HEPA (MRP) in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| ATEX Vacuum Cleaners electrically operated singlephase T3 | Certification Document | descargar |
| Certificate of Compliance | CSA Certificate of Compliance | descargar |

0081
II 2 G/D Ex d IIA T3 Ex tD A21
IP6X – T 200°C
LCIE 03 ATEX 6297

IP65 – T 120°C
LCIE 03 ATEX 6297
- Legally certified explosion proof/dust ignition proof vacuum cleaner
- Less than 10 Ohms of resistivity
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- Designed for the recovery of flammable and toxic powders such as unspent gunpowder and lead contaminants
- Ideal for shooting ranges, army ammunition depots, manufacturers of firearms and pyrotechnic industries
- Single phase explosion proof/dust ignition proof motor
- For dry recovery only. Optional Floater System available for liquid recovery
- All stainless steel AISI 304 construction (except cart). Stainless steel cart available
- Recovery capacity of 10.5 gallons (40 liters)
- Poly liner and clip included for the easy and safe disposal of recovered materials
- Equipped with a 4-wheel dolly
- Complete static dissipating tool kit and suction hose included
| Name | Description | Download |
| EXP1-40L (4W) RE HEPA (FR-P) SERIES Brochure (Metric) | Technical data for EXP1-40L (4W) RE HEPA (FR-P) SERIES in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| EXP1-40L (4W) RE HEPA (FR-P) SERIES Brochure (Imperial) | Technical data for EXP1-40L (4W) RE HEPA (FR-P) SERIES in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| ATEX Vacuum Cleaners electrically operated singlephase T3 | Certification Document | descargar |
Pneumatic (Air) Series

II 2 G/D c IIC T6 (85oC)
LCIE 03 ATEX 6310
- Legally certified explosion proof/dust ignition proof vacuum cleaner
- Less than 10 Ohms of resistivity
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- Designed for the recovery of flammable and toxic powders such as unspent gunpowder and lead contaminants
- Ideal for shooting ranges, army ammunition depots, manufacturers of firearms and pyrotechnic industries
- Pneumatically (air) operated
- Available with Manual Filter Shaker (MFS) system
- For dry recovery only
- All stainless steel AISI 304 construction (except cart). Stainless steel cart available
- Detachable recovery tank (DT) for easy disposal of recovered materials. Recovery capacity of 6.25 gallons (25 liters)
- Poly Liner and retainer clip included for the easy and safe disposal of recovered materials
- Equipped with a 4-wheel cart
- Complete static dissipating tool kit and suction hose included
| Name | Description | Download |
| SS-20L (DT) RE HEPA (FR-P) Brochure (Metric) | Technical data for SS-20L (DT) RE HEPA (FR-P) in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| SS-20L (DT) RE HEPA (FR-P) Brochure (Imperial) | Technical data for SS-20L (DT) RE HEPA (FR-P) in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| ATEX Vacuum Cleaners pneumatically (air) operated to be used in Hazardous Areas | Certification Document | descargar |

II 2 G/D c IIC T6 (85oC)
LCIE 03 ATEX 6310
- Legally certified explosion proof/dust ignition proof vacuum cleaner
- Less than 10 Ohms of resistivity
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- *Cleanroom compatible. Can be used in the pharmaceutical industry with optional stainless steel cart
- Designed for applications where finely pulverized dust is to be recovered
- Pneumatically (air) operated
- Available with Manual Reverse Purge (MRP) system
- For dry recovery only
- All stainless steel AISI 304 construction (except cart). Stainless steel cart available
- Detachable recovery tank (DT) for easy disposal of recovered materials. Recovery capacity of 8.75 gallons (35 liters)
- Poly liner and clip included for the easy and safe disposal of recovered materials
- Equipped with a 4-wheel cart and wire tool basket
- Complete static dissipating tool kit and suction hose included
MRP - Manual Reverse Purge System
The Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge. By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts. This Purging System reduces maintenance down time.
The Manual Reverse Purge (MRP) works by :
1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.
2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.
Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).
Reverse Purge System will cause dust to fall off of the filter.
| Name | Description | Download |
| SS-35L EX (MRP) RE HEPA SINGLE VENTURI Brochure (Metric) | Technical data for SS-35L EX (MRP) RE HEPA SINGLE VENTURI in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| SS-35L EX (MRP) RE HEPA SINGLE VENTURI Brochure (Imperial) | Technical data for SS-35L EX (MRP) RE HEPA SINGLE VENTURI in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| ATEX Vacuum Cleaners pneumatically (air) operated to be used in Hazardous Areas | Certification Document | descargar |

II 2 G/D c IIC T6 (85oC)
LCIE 03 ATEX 6310
- Legally certified explosion proof/dust ignition proof vacuum cleaner
- Less than 10 Ohms of resistivity
- HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- Designed for the recovery of flammable and toxic powders such as unspent gunpowder and lead contaminants
- Ideal for shooting ranges, army ammunition depots, manufacturers of firearms and pyrotechnic industries
- Pneumatically (air) operated
- For dry recovery only. Optional Floater System available for liquid recovery
- All stainless steel AISI 304 construction (except cart). Stainless steel cart available
- Recovery capacity of 10.5 gallons (40 liters)
- Poly Liner and retainer clip included for the easy and safe disposal of recovered materials
- Equipped with a 4-wheel dolly
- Complete static dissipating tool kit and suction hose included
| Name | Description | Download |
| SS-40L (4W) RE HEPA (FR-P) SERIES Brochure (Metric) | Technical data for SS-40L (4W) RE HEPA (FR-P) SERIES in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| SS-40L (4W) RE HEPA (FR-P) SERIES Brochure (Imperial) | Technical data for SS-40L (4W) RE HEPA (FR-P) SERIES in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| ATEX Vacuum Cleaners pneumatically (air) operated to be used in Hazardous Areas | Certification Document | descargar |
Note:
HEPA Filters - efficiency of 99.995% on 0.3 microns - Tested IEST RP-CC001.3 - H14 as per MPPS method EN 1822.
ULPA Filters - efficiency of 99.999% on 0.3 microns - Filtration efficiency of 99.9995% on 0.18 microns - Tested IEST RP-CC001.3 - U15 as per MPPS method EN 1822
Please be advised that all Tiger-Vac HEPA/ULPA Filters are DOP tested when assembled, either upstream or downstream, inside of the vacuum cleaners.
All Tiger-Vac HEPA/ULPA Filters are assembled mechanically with 3 bolts and include a specially designed memory gasket in order to prevent any leaks during the life span of the gasket thus insuring the health and safety of the end user.